Home
About Us
Company Profile
Enterprise culture
Qualification Certification
Development process
Products
Oil-free air compressor
DC air compressor
AC air compressor
Vacuum pump
Air System Solutions
Rail Transit Industry
Laboratory Testing
New energy electric bus
Nitrogen generator
Medical industry
Dental therapeutic apparatus
Portable compressor solution
Post-processing equipment
Adsorption dryer
Membrane dryer
Filter
Hydrogen Energy Solutions
AD-SALE
AST
System Accessories
Electric proportional valve
Hydraulic proportional valve
Pressure Sensors/Transmitters
Mass flow meter/controller
Pressure switch
Level switch
Flow switch
Metal powder sintering
Other
Application
Aerospace
Textile
Pharmaceutical Industry
Refrigeration industry
Rail Transit
Water Treatment & Sewage Treatment
Food & Beverage
Chemical reagent
Automotive industry
Tire manufacturing
Die casting industry
News
Company News
Industry dynamics
Technical exchange
Contact Us
Online message
Recruitment Information
中文
English
One of the applications of Proportionair proportional valve in pharmaceutical industry-speed control of pneumatic double diaphragm pump
Pneumatic double diaphragm pumps use air to control the speed of the diaphragm when pumping various liquids in many manufacturing facilities. Proportion-Air's electronic pressure regulator can easily provide pump speed control for most pneumatic double diaphragm pumps. Generally, our QB3 model provides enough flow to control the speed of most 1 "and 2" pneumatic double diaphragm pumps. For larger pumps, we recommend using our QB1/PSR pressure control assembly. This is a single ring assembly, and its accuracy is lower than our 2 ring assembly. However, in this application, our 2-loop assembly reacts too quickly to the back pressure generated by the pump, which may cause unnecessary oscillations. Our single-loop components do not react as quickly because QB1 only controls the pressure on the PSR dome. This allows the PSR to mechanically adjust to backpressure peaks without having to simultaneously address dome pressure changes.
11
2024
/
03
One of the applications of Proportionair proportional valve in pharmaceutical industry-industrial glass stirrer
Industrial mixers are used in many industries such as chemical, food, glass, pharmaceutical and cosmetics. These machines are designed to promote specific reactions by combining chemicals. Typically, glass beads are used to provide adequate agitation. Glass stirrers can be used to mix many different chemicals. In this sketch, the FQB2 flow controller precisely controls the air flow into the molten material tank to keep it stirred. The flow monitor detects the flow and provides feedback to the FQB2 for closed loop flow control. The FQB2 can control traffic up to 250 SCFM. This flow control packet responds very quickly (<10 ms) and produces repeatable flow control within ± 0.25 percent of full scale.
One of the applications of Proportionair proportional valve in pharmaceutical industry-overvoltage protection
Applications that require precise pressure regulation to fill small volumes benefit from an additional regulator that controls the supply air before it reaches the electro-pneumatic pressure regulator. When the water supply pressure is close to the output pressure, the water output of inches is easier to control. When there is a high pressure differential between the supply and output, the inlet valve may not be able to operate fast enough to prevent large set point overshoot and instability. Repeated or sustained large overshoot can cause damage to the sensor. The SaveAir reduces the air pressure entering the EPR to a preset limit (14.5 psi in the picture), protecting the internal sensor from overpressure, reducing overshoot and instability.
One of the applications of Proportionair proportional valve in pharmaceutical industry-pill coating
The pharmaceutical industry requires precise control in all applications. Proportion-Air's closed-loop technology ensures the accuracy of various processes, including: regulation of atomizing air in pill coating applications, control of pneumatic diaphragm pumps, pill coating, etc. Pills are usually coated with a polymer or polysaccharide coating to extend their shelf life and make them more attractive and easier to swallow. Sometimes the coating contains certain controlled release drugs. When the pills are shaken in the vat or coating pan, our device controls the pressure of the spray by controlling the air atomization (separation into smaller-sized droplets) on the pills. The device can control the pressure of a nozzle with a fixed orifice to produce a perfect flow (such as 30 psi) using pressure or flow. Under pressure, the coating may accumulate in the nozzle over time and cause the flow to decrease-but our product ensures that you get the same pressure when there is no opening at all. Through flow control, when accumulation occurs, our equipment will increase the flow through the nozzle to maintain a consistent spray. Our systems can accommodate vacuum or positive pressure to apply coatings, as well as micro-mist nozzles for fine atomized sprays. The results are precise and repeatable-extremely important in such a highly regulated industry. In the pharmaceutical industry, pill coating is one of the final steps before product packaging and shipping. Not all pills have a coating, but any pill that may have an irritating effect on the stomach is usually coated with a substance that only dissolves in the small intestine. Sometimes the pills are coated to make swallowing easier or for branding purposes only. Regardless of the reason for pellet coating, consistent pressure and/or flow control is required to accomplish the task. Flow can be used very effectively in spray applications to overcome any build-up in the nozzle to maintain consistency. However, in this application, QB3 is used to control the pressure of nitrogen to the coating fluid. The speed sensor is measuring the speed of the conveyor belt and providing this information to the controller. The controller then calculates a command signal to QB3 based on the speed of the conveyor belt. This keeps the spray consistent regardless of the speed at which the pill is moving.